Modern 2.5-storey townhouse
A narrow-lot townhouse built around a central stair and light well: living room at the street, kitchen and dining beside the light well, a quiet ground-floor bedroom at the back, two bedrooms upstairs and a top-floor worship room with terraces. Each floor offers alternative layouts. Designed for urban lots around 5 m wide.
3D view
Loading 3D view…
- Storeys
- 2.5
- Bedrooms
- 3
- Floor area (enclosed)
- 182 m²
- Land width × land depth
- 5 × 20 m
- Flat roof with parapet
- 10.2 m
Floor plans
Design measurements
- Site area
- 100.0 m²
- site width × site depth
- Building footprint
- 75.0 m²
- Σ enclosed room areas on the ground floor
- Site coverage
- 75 %
- footprint ÷ site area
- Floor area (enclosed)
- 182.1 m²
- Σ width × depth of every enclosed room, all levels
- Open area (terraces, balconies)
- 44.1 m²
- Σ width × depth of terraces, balconies and light wells
- Storeys
- 2.5
- an upper level under half the ground-floor area counts as ½
- Height to top of upper level
- 10.20 m
- top level elevation + top level height (roof not included)
- Exterior wall length
- 116.6 m
- Σ room edges not shared with another enclosed room
| Level | Elevation | Height | Enclosed | Open | Ext. walls | Doors / windows |
|---|---|---|---|---|---|---|
| Ground floor | 0.00 m | 3.60 m | 75.0 m² | 0.0 m² | 40.0 m | 5 / 6 |
| Level 2 | 3.60 m | 3.40 m | 72.6 m² | 6.0 m² | 42.8 m | 8 / 4 |
| Level 3 | 7.00 m | 3.20 m | 34.5 m² | 38.1 m² | 33.8 m | 3 / 6 |
| Total | 10.20 m | 182.1 m² | 44.1 m² | 116.6 m |
Stair (design assumptions)
- Ground floor: 21 risers × 171 mm, tread 260 mm, straight flight 1.00 m, run 4.42 m ends on Sinh
- Level 2: 21 risers × 162 mm, tread 260 mm, straight flight 1.00 m, run 5.20 m ends on Sinh
Room · Area
| Ground floor | Stair | 1.00 × 5.20 m | 5.2 m² |
| Ground floor | Front yard · Open | 5.00 × 5.00 m | 25.0 m² |
| Ground floor | Living room | 5.00 × 4.00 m | 20.0 m² |
| Ground floor | Kitchen | 4.00 × 6.20 m | 24.8 m² |
| Ground floor | Hall | 1.00 × 1.00 m | 1.0 m² |
| Ground floor | Hall | 5.00 × 1.20 m | 6.0 m² |
| Ground floor | Bathroom | 1.80 × 2.40 m | 4.3 m² |
| Ground floor | Bedroom | 3.20 × 3.60 m | 11.5 m² |
| Ground floor | Wardrobe | 1.80 × 1.20 m | 2.2 m² |
| Level 2 | Stair | 1.00 × 5.20 m | 5.2 m² |
| Level 2 | Bedroom | 3.00 × 5.00 m | 15.0 m² |
| Level 2 | Bathroom | 2.00 × 2.60 m | 5.2 m² |
| Level 2 | Wardrobe | 2.00 × 2.40 m | 4.8 m² |
| Level 2 | Balcony · Open | 5.00 × 1.20 m | 6.0 m² |
| Level 2 | Study | 3.00 × 5.20 m | 15.6 m² |
| Level 2 | Hall | 1.00 × 5.20 m | 5.2 m² |
| Level 2 | Light well · Open | 2.00 × 1.20 m | 2.4 m² |
| Level 2 | Hall | 3.00 × 1.20 m | 3.6 m² |
| Level 2 | Bathroom | 1.80 × 2.40 m | 4.3 m² |
| Level 2 | Bedroom | 3.20 × 3.60 m | 11.5 m² |
| Level 2 | Wardrobe | 1.80 × 1.20 m | 2.2 m² |
| Level 3 | Stair | 1.00 × 5.20 m | 5.2 m² |
| Level 3 | Terrace · Open | 5.00 × 5.00 m | 25.0 m² |
| Level 3 | Hall | 1.00 × 5.20 m | 5.2 m² |
| Level 3 | Worship room | 3.00 × 3.00 m | 9.0 m² |
| Level 3 | Storage | 3.00 × 2.20 m | 6.6 m² |
| Level 3 | Light well · Open | 2.00 × 1.20 m | 2.4 m² |
| Level 3 | Dry-clothes storage | 2.00 × 2.00 m | 4.0 m² |
| Level 3 | Hall | 3.00 × 1.00 m | 3.0 m² |
| Level 3 | Terrace · Open | 2.30 × 2.20 m | 5.1 m² |
| Level 3 | Laundry | 0.70 × 2.20 m | 1.5 m² |
| Level 3 | Terrace · Open | 2.50 × 1.60 m | 4.0 m² |
| Level 3 | Terrace · Open | 2.50 × 1.60 m | 4.0 m² |
Deterministic measurements from the design model. Areas are measured to wall centrelines. This is not a cost estimate.
Design checks
Geometry 1
-
Room balcony-2 is not fully above a room on the level below. Overhangs need engineering review.
Layout and comfort 4
-
Kitchen (ground floor) has no window to the outside or to a light well. Why
Living rooms, kitchens and bedrooms need a window to the outside, a light well or a terrace for daylight and air.
-
Bathroom (ground floor) has no window and needs mechanical exhaust. Why
Without a window this wet room needs a mechanical exhaust fan to the outside.
-
Bathroom (level 2) has no window and needs mechanical exhaust. Why
Without a window this wet room needs a mechanical exhaust fan to the outside.
-
Bathroom (level 2) is not above another wet room. Why
Wet rooms placed over each other share one drainage shaft and avoid pipes across ceilings.
Feng shui 1
-
Rear opening w-bed-1 is in line with the main door. Why
Feng shui: a main door in line with a rear opening lets energy pass straight through the house (xuyên tâm).
Preferences from common Vietnamese feng shui practice — explained, optional, never a requirement.
Geometry, circulation, daylight and hygiene checks for concept design — not a building-code, structural or planning check.
Illustrative sample. Not reviewed by a licensed architect or engineer. Projects keep the exact version they were created from. A newer version of this sample never changes an existing project.